"""The Zimmer electric gripper on the arm's tool connector (TIO), driven by two digital outputs.
|
|||
|
|
|
||
|
|
Wiring found 2026-10-13 (Cobo π → I/O → Tool(S), outputs set to PNP):
|
||
|
|
DO_1 on -> the gripper closes, DO_2 on -> it opens (a stroke takes ~1 s)
|
||
|
|
AI_1 -> finger position: ~160 open, ~4100-4200 closed on nothing, ~3500 closed on a cup (cup test
|
||
|
|
11:39:12); in between while moving. A close runs to the end once started: DO_1 off half way
|
||
|
|
(AI_1 2730) still ended at 4190 (2026-10-19), so the fingers can't be stopped on a soft cup.
|
||
|
|
A soft plastic cup squeezed flat reads like "empty" (3 of 4 cup closes reached ~4150).
|
||
|
|
DI_1 -> optical sensor under the gripper: 1 while something is below it, not between the fingers (PNP);
|
||
|
|
a held object shows only in AI_1 (gap_mm)
|
||
|
|
Only one output may be on at a time: both on = close and open at once.
|
||
|
|
|
||
|
|
python robot/gripper.py # state
|
||
|
|
python robot/gripper.py open
|
||
|
|
python robot/gripper.py close
|
||
|
|
"""
|
||
|
|
import sys
|
||
|
|
import time
|
||
|
|
|
||
|
|
from robot import arm
|
||
|
|
|
||
|
|
TOOL = 1 # set_digital_output type: 0 cabinet, 1 tool (TIO), 2 extended
|
||
|
|
CLOSE_DO, OPEN_DO = 0, 1 # DO_1, DO_2 (0-based)
|
||
|
|
CLOSED_AI = 400 # AI_1 above this = closed on something (open reads 130-165; an 82 mm metal cup
|
||
|
|
# held in the cup fingers reads ~2200-2300, 2026-10-13)
|
||
|
|
EMPTY_AI = 3900 # closed above this = nothing between the fingers (empty reads 4100-4200, noise +-50)
|
||
|
|
AI_OPEN, AI_SHUT = 140.0, 4160.0 # AI_1 fully open / closed on nothing (2026-10-19)
|
||
|
|
# inner gap (mm) between the fingers, (open, closed), measured with a tape 2026-10-19 (docs/gripper/README.md); the gap
|
||
|
|
# is taken as linear in AI_1: an 82 mm metal cup read 2189-2310 (2026-10-13), the line gives 81-83 mm at the belly
|
||
|
|
GAP_MM = {"tips": (88.0, 59.0), "belly": (96.0, 70.0), "neck": (73.0, 47.0), "shank": (66.0, 39.0)}
|
||
|
|
MOVE_S = 1.5 # s a full stroke takes (measured ~1 s)
|
||
|
|
SENSOR_DI = 0 # DI_1
|
||
|
|
READ_TRIES, READ_GAP_S = 5, 0.1 # get_data now and then answers without the tool I/O: ask again
|
||
|
|
|
||
|
|
|
||
|
|
def state():
|
||
|
|
for _ in range(READ_TRIES):
|
||
|
|
d = arm.cmd("get_data")
|
||
|
|
if all(k in d for k in ("tio_ain", "tio_din", "tio_dout")):
|
||
|
|
break
|
||
|
|
time.sleep(READ_GAP_S)
|
||
|
|
else:
|
||
|
|
raise ConnectionError("the arm controller sends no tool I/O")
|
||
|
|
ai = d["tio_ain"][0]
|
||
|
|
return {"closed": ai > CLOSED_AI, "holding": CLOSED_AI < ai < EMPTY_AI, "object_in_front": bool(d["tio_din"][SENSOR_DI]),
|
||
|
|
"ai": d["tio_ain"], "do": d["tio_dout"], "di": d["tio_din"], "gap_mm": round(gap_mm(ai))}
|
||
|
|
|
||
|
|
|
||
|
|
def gap_mm(ai, where="belly"):
|
||
|
|
"""Inner gap (mm) between the fingers at `where` (GAP_MM) for an AI_1 reading: the held object's width there."""
|
||
|
|
opened, closed = GAP_MM[where]
|
||
|
|
f = min(1.0, max(0.0, (ai - AI_OPEN) / (AI_SHUT - AI_OPEN)))
|
||
|
|
return opened + f * (closed - opened)
|
||
|
|
|
||
|
|
|
||
|
|
def _out(index, value):
|
||
|
|
r = arm.cmd("set_digital_output", type=TOOL, index=index, value=int(value))
|
||
|
|
if r.get("errorCode") != "0":
|
||
|
|
raise RuntimeError(f"set_digital_output failed: {r}")
|
||
|
|
|
||
|
|
|
||
|
|
def close(wait=True):
|
||
|
|
_out(OPEN_DO, 0) # never both on
|
||
|
|
_out(CLOSE_DO, 1)
|
||
|
|
if wait:
|
||
|
|
time.sleep(MOVE_S)
|
||
|
|
return state()
|
||
|
|
|
||
|
|
|
||
|
|
def open_(wait=True):
|
||
|
|
_out(CLOSE_DO, 0)
|
||
|
|
_out(OPEN_DO, 1)
|
||
|
|
if wait:
|
||
|
|
time.sleep(MOVE_S)
|
||
|
|
return state()
|
||
|
|
|
||
|
|
|
||
|
|
if __name__ == "__main__":
|
||
|
|
what = sys.argv[1] if len(sys.argv) > 1 else "state"
|
||
|
|
print({"open": open_, "close": close}.get(what, state)())
|