Turn the waist with the arm on a hand-over, recover stopped picks and improve follow tracking

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
2026-10-29 15:55:03 +09:00
co-authored by Claude Opus 5.5
parent 390ec9db99
commit e8d651da49
24 changed files with 728 additions and 200 deletions
+3 -3
View File
@@ -25,9 +25,9 @@ CLOSED_AI = 400 # AI_1 above this = closed on something (open reads
# held in the cup fingers reads ~2200-2300, 2026-10-13)
EMPTY_AI = 3900 # closed above this = nothing between the fingers (empty reads 4100-4200, noise +-50)
AI_OPEN, AI_SHUT = 140.0, 4160.0 # AI_1 fully open / closed on nothing (2026-10-19)
# inner gap (mm) between the fingers, (open, closed), measured with a tape (docs/gripper/README.md; the straight part
# "shank" not measured on these fingers, the earlier one kept); the gap is taken as linear in AI_1
GAP_MM = {"tips": (87.0, 63.0), "belly": (94.0, 68.0), "neck": (57.0, 30.0), "shank": (66.0, 39.0)}
# inner gap (mm) between the fingers, (open, closed), measured by the owner (docs/gripper/README.md; the neck and the
# straight part "shank" not measured again, the earlier ones kept); the gap is taken as linear in AI_1
GAP_MM = {"tips": (100.0, 73.0), "belly": (102.0, 77.0), "neck": (57.0, 30.0), "shank": (66.0, 39.0)}
MOVE_S = 1.5 # s a full stroke takes (measured ~1 s)
SENSOR_DI = 0 # DI_1
READ_TRIES, READ_GAP_S = 5, 0.1 # get_data now and then answers without the tool I/O: ask again