{ "joints": [ -297.606897, -78.356094, -28.782753, -143.133593, 40.177249, -277.868113 ], "flange": [ 51.754108, 468.431956, -181.97017, 83.715142, 46.657319, -138.490175 ], "note": "fingers around the cup, 2026-10-13 ~18:40; cup position measured after lifting", "cup": { "x": -128.0, "y": 628.0, "top": -261.0, "width": 76.5 }, "grasp_base": [ -128.0, 628.0, -301.0 ], "tcp_offset_flange": [ 103.6, -88.3, 219.7 ], "tcp_offset_note": "corrected 2026-10-27 by hover readings at three cup spots (data/hover_readings.json): the taught point carried the camera's cup-centre error (-10.0, +5.2 mm in the arm frame); the camera's own error is fixed in vision/objects.py ROUND_FIX_MM" }